3.3.1  PotentiometerBox, SK TU3-POT 
The frequency inverter can be controlled directly from the device using 
the PotentiometerBox. No additional external components are required. 
The motor can be started, stopped and the direction of rotation changed 
by means of the buttons. A change of direction of rotation is triggered by 
pressing the Start or Stop keys for approx. 3 sec.. 
The required frequency setpoint for starting after enabling (green key) is 
set with the potentiometer. 
The LEDs indicate the status of the FI. If an inactive error is present (red 
LED flashing), this can be acknowledged by pressing the STOP key 
 
Note:  The PotentiometerBox must be activated via parameter P549 “PotentiometerBox 
Function” using the setting {1} “Setpoint frequency”. 
I/O key  START/STOP (green/red) 
To enable or block the output signal. 
Potentiometer  0 … 100% 
Sets the output frequency between f
min
 (P104) and f
max
 (P105). 
Off 
 
No error 
  Flashing  Inactive error 
  On  Active error 
Green LED 
Off 
 
Frequency inverter switched off, enabled with 
rotation direction to the right 
 
Flashing 1: short on, long 
off 
Frequency inverter switched off, enabled with 
rotation direction to the left 
 
Flashing 2: short on, short 
off 
Inverter switched on with direction of rotation to the 
left 
  On 
Inverter switched on with direction of rotation to the 
right 
 