SK 54xEUsers Manual for Frequency Inverters
82 BU 0505 EN-3021
Control with the SimpleBox
If P549=1 is set and the operating value display P000 is selected, the drive can be controlled with the
SimpleBox on the FI.
Depressing the button for a long time starts the drive, pressing briefly stops it. The speed of rotation
can be controlled in the positive and negative range by means of the rotating knob.
Note
Stopping the drive
In this operating mode, the drive can only be stopped with the button in the operating value display (short press)
or by switching off the mains voltage.
Menu structure with the SimpleBox
P0--
_ _ _ _
P1--
P2--
P4--
P5--
P6--
P7--
P001
P002
P10 0
P10 1
P114
P200
P201
P220
P400
P401
P483
Operating value display
(or operational)
following mains ON
P3--
P300
P301
P327
P003
Fig. 12: SimpleBox, SK CSX-0 menu structure
NOTE: Some parameters, e.g. P465, P475, P480…P483, P502, P510, P534, P701…P706,
P707, P718, P740/741 and P748 have additional levels (arrays), in which further
adjustments can be made, e.g.:
P 01
P502
P 02
OFF
OFF
Setting:
Master function value 1
Setting:
Master function value 2
ENTER
ENTER
ENTER
VALUE
Pos: 111 /Anleitungen/ Elektronik/F U und Starter/3. Anzeige, Bedi enung und Optionen/SK 5 xxE/3.2.11 Potentio meterBox, SK TU3-P OT @ 0\mod_1327504804 184_388.docx @ 7095 @ 377 @ 1