Troubleshooting
6-33
Part 1073401_07
E 2021 Nordson Corporation
No faults >
Ready LED is illuminated >
No hot melt output from all applicators >
Motor is not turning >
All motor start conditions are correct >
Tank setpoint temperature is correct
T.4.1
?
+
Is the motor excessively
hot?
+
Is the electrical harness
that exits the motor junction
box connected to the
receptacle underneath the
melter?
Allow the motor to cool and
then automatically start
once its internal thermostat
resets.
+
Does swapping the main
board with a known good
board correct the problem?
Connect the harness.
Stop.
Replace the motor.
Refer to Section 7, Parts.
+
Is indicator DS7 on the
main board illuminated?
Replace fuses F11 and
F12.
P/N 1031203