Operating Parameters
B-3
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
4 Ready Delay Time
Description:
The amount of time that will elapse after all of the components have
reached their set-point temperature before the ready LED will turn on.
The ready delay time only functions when the temperature of the tank, at
the time the melter is turned on, is more than 27 °C (50 °F) from its
set-point temperature. The ready delay time begins when all components
are within 3 °C (5 °F) of their respective set-point temperature.
Value:
0 to 60 minutes
Resolution:
1 minute
Default Value:
0 minutes
Format:
Use:
The ready delay allows the contents of the tank an additional amount of
time to heat before pump turns on.
NOTE: The time remaining on the ready delay is indicated in minutes in
the right display at the end of every automatic scan cycle. When the
delay time reaches 1 minute, the time remaining appears in seconds.
7 Motor Off Delay
Description:
Determines the amount of time the motor will remain on after the
switching device turns off.
Value:
0 to 360 seconds
OR
- - - - (infinite)
Resolution:
seconds
Default Value:
0 seconds
Format:
Use:
This parameter functions only when a switching device (switched
handgun hose, footswitch, etc.) is connected to the switch receptacle.
8 Automatic Pump On
Description:
Determines if the pump can be enabled before the melter is ready.
Value:
0 = disabled or 1 = enabled
Resolution:
Default Value:
1 (enabled)
Format:
Use:
If enabled, the pump can be enabled before the melter is ready. Once
enabled, the pump will start automatically when the melter is ready.
If disabled, the pump must be started by pressing the pump key after the
melter is ready.
NOTE: If automatic pump on is disabled (0) while the pump is running,
the pump will remain on until the pump key is pressed.

Table of Contents

Other manuals for Nordson DuraBlue D16L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson DuraBlue D16L and is the answer not in the manual?

Nordson DuraBlue D16L Specifications

General IconGeneral
BrandNordson
ModelDuraBlue D16L
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals