System Setup
2-11
Part 161250002
E 2018 Nordson Corporation
NOTE: If the spray gun is triggered on during power-up or wake up from
disable, the trigger LED blinks at a fast rate. Release the trigger and repeat
the sleep/wake up cycle.
Entering Configuration Mode
To enter configuration mode:
S Controller Power OFF Press and hold the Plus and Minus buttons
on the kV/uA panel while turning on power.
S Controller Power ON Press and hold the Plus and Minus buttons
while pressing the Enable/Disable button.
After 1 second all panels flash CF for 3 seconds. After 3 seconds the kV/
μA
panel displays F − 1 for function 1. The controller is now in configuration
mode.
To save your settings and exit Configuration Mode, press the
Enable/Disable button.
Atomizing Air
(Classic)
Total Flow
(Smart Flow)
Setting/Display
Select Charger Settings
KV/μA Setting/Display
KV/uA Selection
Control
Smart Flow Mode
Indicator
Flow-Rate Air
(Classic)
Powder Flow Rate
(Smart Flow)
Setting/Display
Enable/Disable
Trigger LED
Figure 2-11 Controller Interface