Spray Gun Power Supply Resistance Test
Use a megohm meter to check the resistance of the power supply, from the
J23 feedback terminal at the connector to the contact pin inside the front
end. The resistance should be between 225335 megohms. If the reading
is infinite, switch the meter probes. If the resistance falls outside this range,
replace the power supply.
NOTE: There are multiple variables that can affect the MegOhm readings
of your meter (temperature and measurement voltage). If the MegOhm
meter output voltage differs from the 500 V setting, it will have a direct
impact on the measurement accuracy. Measurements should also be taken
at room temperature 22
_
C or 72
_
F. Allow time for the multiplier to cool to
room temperature for repeatable results.
J23 (YELLOW)
FEEDBACK
J22 (BLACK)
COMMON
J21 (RED)
OSC
225-335 Megohms at 500 VDC
Figure 5-8 Power Supply Resistance Test