System Setup
2-12
Part 161250002
E 2018 Nordson Corporation
Function Settings
To change functions, press the Plus or Minus buttons on the kV/μA panel.
To change function values press the Plus or Minus buttons on the Flow Air
panel.
Function No. Name Settings Default
1 Gun Type 0 = Encore 0
2 Fluidizing 0 = Hopper, 1 = Box, 3 = Disable 0
3 Electrostatic Control 0 = Custom, 1 = Classic 0
4 Powder Flow Control 0 = Smart, 1 = Classic 0
5 Cable Length 0 = 6 meters, 1 = 12 meters, 2 = 18 meters 0
NOTE: Refer to the Operation section for explanations of the differences in
Electrostatic Control and Powder Flow Control modes.
Exiting Configuration Mode
To accept all function values and exit Configuration Mode, press the
Enable/Disable button. The controller can now be operated normally.