Converting an FP-200 Extrusion Gun to an FP-200 Swirl Gun
6
Part 237494_02
E 2012 Nordson Corporation
Disassembling the Extrusion Gun
Make sure you have completed the Preparing to Convert an FP-200 Gun
procedure before proceeding.
See Figure 3 for the following procedure.
1. Unthread and remove the outlet air line swivel fitting from the outlet air
line universal elbow.
2. Disconnect the mounting bracket from the gun mounting plate.
3. Disconnect the outlet air line universal elbow from the bulkhead fitting
and set it aside. It will be used later.
4. Disconnect the bulkhead fitting and mounting bracket from the extrusion
air line universal elbow.
5. Extract the bulkhead fitting from the mounting bracket.
5
4
2
3
1
6
Figure 2 Disconnecting the Extrusion Air Line (Top View)
1. Gun mounting plate
2. Outlet air line universal elbow
3. Outlet air line swivel fitting
4. Bulkhead fitting (including washers
and locking nut)
5. Extrusion air line universal elbow
6. Mounting bracket