Specifications
Specifications are subject to change without notice.
Electrical
Main input voltage 85240 Vac, 50/60 Hz
1 , 10 amp (300 VA)
Gun output 621 Vdc
Maximum current 600 mA
Maximum short circuit current 50 mA
ANSI/ISA-S82.01 Pollution Degree 1
Overvoltage Category III
Pneumatic
Operating Air Pressures
Minimum input air pressure 5.6 bar (80 psi)
Maximum input air pressure 7 bar (100 psi)
Typical Air Pressures
Flow rate air 2 bar (30 psi)
Atomizing air 1 bar (15 psi)
Gun air 0.6 bar (10 psi) fixed
Air Supply Quality
Main input air must be clean and dry. Use a regenerative desiccant or
refrigerated air dryer capable of producing a 3.4 _C (38 _F) or lower
dewpoint at 7 bar (100 psi). Install a filter system with prefilters and
coalescent type filters capable of removing oil, water, and dirt in the
submicron range.