EasyManua.ls Logo

Nortel DMS-250 - Layer 3 Facility Data Correlation

Nortel DMS-250
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Datafill and subscription parameters 9-5
Digital Switching Systems DMS-250 ISDN Reference Manual MWC14 (CSP14)
Table 9-2
Layer 2 database correlation
Description DMS-250 switch
Associate D-channel with PRI Table TRKSGRP
Field: DCHNL
Value: Timeslot on DS-1 of the PRI
D-channel
Data rate of D-channel Table TRKSGRP
Field DCHRATE
Value: 56 kbit/s, 64 kbit/s
—end—
Layer 3 facility data correlation
The correlation of layer 3 facility data is shown in Table 9-3.
Table 9-3
Layer 3 database correlation
Description
DMS-250 switch
Q.931 interface identifier Table LTCPSINV
Field IID
Value: 0
Note:
When datafilling multiple DS-1s
per trunk group, a unique IID must be
used for each DS-1.
Q.931 call reference value length Table TRKSGRP
Field CRLENGTH
Value: 2
B-channel selection Table TRKGRP
Field SELSEQ
Value: ASEQ, DSEQ, or WIDEBAND
Loss and level Table TRKGRP
Field PADGRP
Value: NPDGP
User-network interface Table TRKSGRP
Field IFCLASS
Value: NETWORK
—continued—