– 69 –
6.2.3 Cleaning in the event of spillage into the device
- Follow the steps described in 6.2.1 and 6.2.2.
- Remove the upper collection containers from the tower and
clean if necessary.
- Remove the collection safety and clean if necessary.
- In the case of spillage of large quantities of uid, slide the
lower collection containers from the underside of the extraction
hood and clean if necessary.
Follow the steps in the reverse order to make the device ready
for cooking again.
– Press the
button after all parts are reinstalled.
6.2.4 Cleaning the Monoblock recirculation lter (only
with recirculation)
If recirculation has been selected, the device has been
connected to an built-in recirculation box with a Monoblock
recirculation lter.
Regenerating the Monoblock recirculation lter:
– The Monoblock can be regenerated up to 12 times. This is
done in the oven.
– Place the lter in the oven for 1 hour at 120°C. Provide
sucient fresh air in the room where the oven has been
placed, as smells can be released. Smells can be released
when baking certain kinds of sh. The best solution for this is
to immediately regenerate the lter.
After cleaning:
– Return the Monoblock recirculation lter into the built-in
exhaust box.
– Press the
control key for 3 seconds.
1821_110119_GA2.indd 69 19/02/18 23:14