SUMMARY 1. SUMMARY
Function Description
Protected switch
The primary feature of VARICAM can set and change the switch output easily. However,
there are switch outputs which are not wanted to set and change easily. The protected switch
function can solve these kinds of problems.
The protected switch function can be used for switch Nos. 1-10.
The func
tion is used in such cases to prevent the setting from being changed in the usual
manner. To change or delete a protected switch, the protected s
canceled first.
For more setting details, refer to “8-3. Protected Switch Function”.
Multi-dog
ON/OFF angle setting (dog) is designated ten times each switch output.
Dog number is 0 to 9.
For more setting details, refer to “9-2. Sets the Multi-Dog”.
Program
This function is registering one switch output pattern as a program. The setup change is easy
by switching this program.
(This function is available to VS-5FD(-1) and VS-5FX(-1).)
Ex.
VS-5FX can designate the switch output maximum 40-point at each 16-program.
TEACH setting
TEACH setting is able to set ON/OFF position of each switch by actually moving the machine.
For more setting details, refer to “9-1. Sets by Teaching”.
Output HOLD
This function keeps the state of the switch output when the mode changes from “RUN” to
another mode.
For more setting details, refer to “8-6. Output HOLD Function”.
External origin set
Origin-point (zero-point) setting is executed by an external signal input.
For more setting details, refer to “8-9. External Origin Set Function”.
If this function is using, “Current position HOLD function” will not be able to use because these
two functions are sharing an input pin.
(This function available to VS-5FX(-1)).