64
64
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer
Trouble Shooting
PROBLEM CAUSE SOLUTION
Machine will not operate Battery not inserted correctly
Low battery charge
Faulty battery
Insert battery (pages 15 - 20)
Recharge battery (See battery & charger instructions)
Replace battery (pages 15 - 20)
Vacuum not operating Vacuum not turned on
If vacuum light on but no vacuum
operation
Turn on vacuum (pages 33 - 43)
Contact service agent
Poor water pick-up Waste-water tank full
Clogged / blocked vacuum hose
Loose hose connections
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Empty waste-water tank (pages 50 - 55)
Remove and clean (pages 50 - 55)
Push tight connections (pages 50 - 55)
Remove and clean (pages 50 - 55)
Remove and clean (pages 50 - 55)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
No brush / scrub function
Brush overloaded
Reset machine (pages 33 - 43)
Clean-water tank empty
Fill clean-water tank (pages 27 - 32)
Adjust tap as desired (pages 27 - 32)
Remove and clean
operating
Too much load on the brush system If cut out engages then the surface is to rough & an
alternative machine may be required
EN
Model - TTB1840 36V
Brush
Motor
Vac
Motor
Brush
Sizes
Pad
sizes
Net
Weight
Gross
Weight (Full)
175 W 100 W 400 mm 360 mm 34 kg 52 kg
Protection
Class
*Run Time
Water
Fluid
Flow
Sound Pressure (LpA)
Cleaning speed
IPX4
*60 Min
18 L 0 - 0.7L/Min
65
dB(A)
±0.5 dB
0 - 4.2 KPH
Brush
Speed
Brush
Pressure
Pad
Pressure
Dimensions
Hand Arm
Vibration
*Charge Time
150 RPM 24.61g/cm
2
21.85g/cm
2
Width = 520 mm
Length = 850 mm
Height = 1132 mm
1.7 m/s
2
*80%=60 Min
*100%=120 Min