26
Failure to rectify the problem or in the event of a breakdown
contact your Nacecare dealer
or the Nacecare Technical helpline
9 00 1 905 795 0122
( see back page for company addresses or dealers stamp)
PROBLEM CAUSE SOLUTION
Machine will not operate Missing or blown fuses
Key in the ‘OFF’ position
Low battery charge
Machine is connected and charging
Fit or replace fuse (page 23)
Turn key to ‘ON’ position (page 9)
Charge batteries (page 22)
Take off charge (page 22)
Vacuum will not operate Waste water tank full Empty waste water tank (page 19)
Poor water pick-up Waste-water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket lter cloogged/blocked
Separator lter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged oor-tool blades
Low battery charge
Empty waste-water tank (page 19)
Remove and clean (page 10)
Push tight connections (page 10)
Remove and clean (page 19)
Remove and clean (page 19)
Clean and ret (page 19)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Recharge batteries (page 22)
No brush / scrub function No brushes tted
Brush deck raised
Check and t (page 11)
Lower brush deck (page 14)
Little or no water ow Clean-water tank empty
Clean-water tank lter blocked/ clogged
Incorrect water ow setting
Brush deck raised
Fill clean-water tank (page 19)
Remove and clean (19)
Adjust as desired (page 15)
Lower brush deck (page 14)
Little or no dosing solution ow Chemical dosing tank empty
incorrect dosing ow setting
Fill dosing-tank (page 13)
Adjust as desired (page 15)
Machine just ‘stops’ while
operating
To much load on the brush system Reset the machine using the key and
decrease the brush load to best suit
the oor type (page 19)
Trouble-Shooting