5. GLOSSARY AND REFERENCES
The following terms are associated with the 6002 addressable control and indicating equipment.
Term Description Reference
Access levels Hierarchical levels to gain access to specific control and configuration
functions.
EN 54-2, Control and
indicating equipment
Alarm Condition When an event from an initiating device (eg detector) is recognized as a
fire.
EN 54-2, Control and
indicating equipment
Alarm signal The audible or visual signal to the building occupants that a Fire
Condition has occurred. Alarm signals are generated by audio/visual
alarm devices.
Control and
indicating
equipment
This equipment, that monitors devices displays events, initiates alarm
devices, and allows control of the fire detection and alarm system.
EN 54-1, General and
definitions
Disable Condition When an alarm zone (input devices or outputs) will not report alarm or
fault events, nor respond to any event even reported by another zone.
EN 54-2, Control and
indicating equipment
Fault Condition When an event (either from an input device, a transmission path, or
within the control and indicating equipment) is recognized as a fault.
EN 54-2, Control and
indicating equipment
Fire detection and
alarm system
All detection, control and alarm equipment, including detectors, manual
call points, control and indicating equipment, and audio & visual alarm
devices.
EN 54-1, General and
definitions
Initiating device An input device, such as a smoke detector, manual call point or input
module that signals an event (such as a fire) to the control and
indicating equipment.
The following documents are associated with the 6002 addressable control and indicating equipment and
accessories.
Description Reference
6002 Control and indicating equipment 31-0065 datasheet; 33-0019 user manual
32-0043 installation manual
6002-06 Addressable repeater panel, LCD display, 24 V 31-0070 datasheet
6002-07 Addressable repeater panel, LCD display, AC 31-0071 datasheet
Website
For more information, including product datasheets and other support material, please view our website at
www.numens.com.
Contact Us
For sales and specific enquiries, please contact our sales office by telephone or email. Enquiries can also be submitted
through our website.
Numens
9 Xizhao Road, Innovative Industrial Area
Dong Qian Lake, Ningbo
Zhejiang, China 315121
T: +86 574 8281 7218
F: +86 574 8300 1379
E: sales@numens.com
Please note that China time is UTC (GMT) +8 hours.