TROUBLE-SHOOTING
If the Lift does not work properly, refer to the following trouble-shooting guide. If the problem cannot be resolved,
call Technical Service at 704.864.2470.
No power supply, or feed line is cut
Check the power supply at the facility breaker
box and the power supply box.
Top Limit Switch is engaged or
defective
If engaged: loosen actuator mechanism.
If defective: replace switch.
Motor starts, Lift does not move
Check vehicle for empty weight. Unload
unnecessary weight from vehicle.
Lower Lift and fill oil reservoir. Check for
leakage. Call Technical Service if leakage is
observed.
Defective Hydraulic Valve
Check for leakage. Call Technical Service if
leakage is observed.
Check for leakage. Call Technical Service if
leakage is observed.
Leakage in the Hydraulic System
Check for leakage. Call Technical Service if
leakage is observed.
Lift is resting on the mechanical locks
Press the Raise Button until the locks are
clear, engage the Lock Release Lever.
An obstacle is restricting the Lift from
being lowered
Press the Raise Button until the obstacle is
freed. Remove the obstacle.
Lowering valve is defective
Lock Release Cable is broken or
defective
Call Technical Service or your manufacturing
representative to purchase a new Lock
Release Cable.
The Lift lowers unexpectedly
Lowering valve is defective
REPLACEMENT PARTS
ONLY USE NUSSBAUM ORIGINAL EQUIPMENT PARTS TO REPAIR THE LIFT