Details the applications, temperature/CO2 control, and chamber features of the EC 160 CO2 Incubator.
Lists key technical parameters like temperature range, sensor type, control system, capacity, and power.
Details factory-fitted and optional accessories available for the EC 160 CO2 Incubator.
Specifies the recommended ambient conditions for safe and optimal operation of the CO2 Incubator.
Provides instructions for safe handling and transportation of the instrument by trained staff.
Details the process of unpacking the incubator and checking for included components and damage.
Outlines the power requirements and emphasizes the need for grounded sockets and circuit breakers.
Guides on selecting a suitable and safe location for the instrument, considering user access and ventilation.
Provides a visual overview of the EC 160 CO2 Incubator, labeling its main components.
Explains the control panel layout and the function of the F1-F4 buttons for device operation.
Instructions for installing shelves and the humidity tray inside the incubator chamber.
Guides on correctly installing biological filters inside and outside the incubator chamber.
Details the procedure for connecting and replacing the CO2 gas tank and regulator.
Step-by-step guide on how to power on the EC 160 CO2 Incubator and initial system checks.
Describes the main operating screen displaying chamber temperature, CO2, and set values.
Explains how to use the set button to adjust chamber temperature, CO2, and alarm values.
Details how to view and adjust graphical representations of temperature and CO2 over time.
Describes the help function for accessing error explanations, warnings, and user advice.
Explains how to navigate the main menu system using the menu and function buttons.
Describes the two types of disinfection processes available: NüveDis™ 90°C and UV Disinfection.
Step-by-step guide for performing the 90°C NüveDis™ disinfection cycle.
Instructions for using the nUVeRay™ UV lamp for chamber disinfection.
Information for technical service personnel regarding device updates, calibration, and parameter settings.
Guides on accessing and configuring user settings, including security and memory options.
Details how to lock the control system and change the user password for device security.
Explains how to access and manage operating and error records stored within the device.
Recommendations for regular maintenance tasks, including filter and pump replacement schedules.
Instructions for safely cleaning the incubator chamber, components, and exterior surfaces.
Lists common error codes displayed by the incubator and their potential causes.
Instructions regarding the replacement of fuses, emphasizing authorized personnel.
Information on the GSM alarm module for remote failure notifications via SMS or email.
Step-by-step guide for connecting the optional GSM module to the incubator's NC contact output.
Details the function of the CO2 changeover unit for continuous gas supply.
Explains the software for user monitoring, saving operations, and tracking CO2/temperature data.
Describes the port for external measurements or operating internal instruments like a magnetic stirrer.
Information on the remote alarm system for notifications of various alarm conditions.
Instructions for mounting the remote alarm kit to a wall or board near the device.
Details the UV disinfection kit used for chamber sterilization after use.