Airflow (LFM) /
Ambient
Temperature
Cable Type
Airflow Direction
Heatsink to Port Port to Heatsink
Passive Cables TBD TBD
Mellanox Active W
Cables
TBD TBD
Regulatory Safety: CB / cTUVus / CE
EMC: CE / FCC / VCCI / ICES / RCM / KC
RoHS: RoHS Compliant
MCX653105A-HDAT Specifications
Phys
ical
Adapter Card Size: 6.6 in. x 2.71 in. (167.65mm x 68.90mm)
Connector: Single QSFP56 InfiniBand and Ethernet (copper and optical)
Prot
ocol
Sup
port
InfiniBand: IBTA v1.3
a
Auto-Negotiation: 1X/2X/4X SDR (2.5Gb/s per lane), DDR (5Gb/s per lane), QDR (10Gb/s per lane), FDR10
(10.3125Gb/s per lane), FDR (14.0625Gb/s per lane), EDR (25Gb/s per lane) port, HDR100 (2 lane x 50Gb/s
per lane), HDR (50Gb/s per lane) port
Ethernet: 200GBASE-CR4, 200GBASE-KR4, 200GBASE-SR4, 100GBASE-CR4, 100GBASE-KR4,
100GBASE-SR4, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-
LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-
CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR
Data Rate InfiniBand SDR/DDR/QDR/FDR/EDR/HDR100/HDR
Ethernet 1/10/25/40/50/100/200 Gb/s
PCI Express Gen3/4: SERDES @ 8.0GT/s/16GT/s, x16 lanes (2.0 and 1.1 compatible)
Ada
pter
Card
Pow
er
Voltage: 12V, 3.3VAUX
Power Cable
Typical Power
b
Passive Cables 19.3W
Maximum Power Please refer to ConnectX-6 VPI Power Specifications (requires MyMellanox login
credentials)
Please make sure to install the ConnectX-6 card in a PCIe slot that is capable of supplying the
required power and airflow as stated inthe below table.