60
616 01 1017 02
Heat Pump Heating Airflow
COMFORT (default)
 Heat Pump airflow is varied depend
ing on outdoor temperature to maximize comfort.
EFF 325
 Fixed airflow used to achieve specified ratings.
This is nominally 325 CFM/ton, but will vary if a 2stage out
door unit is used.
EFF 350
 Fixed airflow used to achieve specified ratings.
This is nominally 350 CFM/ton, but will vary if a 2stage out
door unit is used.
MAXIMUM
 400 CFM/ton.
Cooling Airflow
COMFORT (default)
 cooling airflow is varied depending on
humidity and temperature demands settings. This selection en
ables the full dehumidify and comfort capabilities of the system.
When COMFORT is not selected, the unit will not run reduced
airflows for dehumidification.
EFF 325
 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 325
CFM/ton, but will vary if a 2stage outdoor unit is used.
EFF 350
 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 350
CFM/ton, but will vary if a 2stage outdoor unit is used.