Zone Weighting
This configuration allows the installer to select the “size” of
each zone. Typically, living areas are assigned a larger
weight %, or importance factor, than bedrooms and smaller
areas. The Zone weight affects what heating and cooling
stages are used to condition the calling zones. If o nly one
zone is calling for conditioning and that zones has a low
weight, only low stage may be used. Example: if a zone
weighted a 30% is calling for conditioning, the system may
not run until more zones are calling.