44015503TH Rev. 1
137 /
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
• The above displays are switched to the following by pressing the MENU up-
arrow (
) button.
BELT=****
FRM [***] ( xxx )
BELT: A belt motor constant-speed timer value (a set input/output value) (in
hex).
F
RM: Three asterisks in square brackets ([***]) identifies a read frame
thermistor AD value (in hex). Three cross signs in brackets ((***))
identifies a frame temperature (in Celsius).
• T
he above displays are switched to the following by pressing the MENU up-
arrow (
) button.
DB:k**y**m**c**
DB: A developing voltage setting table identification number (in hex).
• The above displays are switched to the following by pressing the MENU up-
arrow (
) button.
TR1:k**y**m**c**
TR2:k**y**m**c**
TR1: A transfer voltage parameter VTR1 table identification number (in hex).
TR2: A transfer voltage parameter VTR2 table identification number (in hex).
• The above displays are switched to the following by pressing the MENU up-
arrow (
) button.
TROFF:**
BELT xxx(***)
TROFF: A transfer off voltage setting table identification number (in hex).
BELT: Three cross signs and a minus sign (xxx-) identifies a read belt
thermistor AD value (in hex). Three asterisks and a minus sign (***-)
identifies a belt temperature (in hex).
5
. Repeat steps 2 through 4 when necessary.
6. Press the CANCEL button to end the test (the state in step 1 is restored).