44015503TH Rev. 1
140 /
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
When the displayed option is DENS ADJ PAR-SET:
T
he setting for the density adjustment parameter is displayed.
When the displayed option is AUTO CALIBRATION:
The density sensor sensitivity adjustment value is automatically set (the
ONLINE lamp starts blinking) is performed.
When the test ends, the upper display shows the result of the test (OK or a
error name), the lower display shows ‘****RESULT’.
OK
DENS ADJ RESULT
Pressing the MENU up-arrow ( ) button displays the next test result. Pressing
the MENU down-arrow ( ) button displays the preceding test result. Press the
BACK button to return to step 2.
Pressing the CANCEL button during the test cancels the test (turning on the
ONLINE lamp), restoring the state of step 2.
Remark: T
he following message appears while the printer is initialized or issues an
alarm or when the cover is open.
NG
DENS ADJ RESULT
4. Repeat step 3 when necessary.
5. Press the BACK button to end the test (the state if step 1 is restored).
Density adjustment test item
Option Detail
DENS ADJ EXECUTE Executes density adjustment.
DENS ADJ PAR-SET Sets a control value for auto density adjustment.
DENS ADJ RESULT Displays the result of density adjustment.
AUTO CALIBRATION Automatically sets a density sensor sensitivity
correction value.