Maintenance
Start maintenance (wiper blades check, capping unit cleaning, cleaning)
1
PRINTER READY
01: PAPER / 1626mm
2
MAINTENANCE
2
START MAINTENANCE
3
>START MAINTENANCE
OK?
4
IP7-264 Cleaning swab (Thick)
* IP6-264 is also included in the IP6-271 daily
maintenance kit A.
5
1ST WIPING OPERATION
PLEASE WAIT 1:00
Carriage stops moving.
6
OPEN COVERS, CLEAN
CAPS AND CHECK WIPER
7
The procedure
is nished.
Continue the procedure
from step 2.
GOOD
BAD
If you find that the wiper blades are damaged or
dirty, execute REPLACE WIPER BLADE to replace
the wiper blades after START MAINTENANCE has
finished.
8
IP6-272 Cap cleaning liquid A
* IP6-272 is also included in the IP6-271 daily
maintenance kit A.
* To keep the cap cleaning liquid clean, do
not soak the cleaning swab (thick) in the cap
cleaning liquid bottle again after you have
cleaned the caps with it.
* You can clean the entire capping unit with
one cleaning swab (thick) soaked once in cap
cleaning liquid.
42