Printer mode
LED CONDITION
LCD
ALARM SELECT
Operator
alarm
Fault alarm
Thermal
alarm
COVER OPEN
DATA REMAIN
HEAD Thermal
SP Thermal
Contents
The access cover is open.
A status where the printer alarms cover
open with data remained inside the
printer (the space is in motion) and then
the cover is closed.
For details see paragraph (2) alarm
displqy.
A thermal alarm of print head. Printer
is changed to one-way printing mode.
A thermal alarm of space motor. Line
spacing wait command interrupts the
process.
ON
OFF
OFF
ON
Trouble Shooting
Close the access cover. (If the
problem cannot be solved, then
go to C .)
•It is recovered dutomatically.
•1)Replace Print Head.
2)Replace PDA-PCB.
•It is recovered dutomatically.
•1)Replace PMA-PCB.
Remarks
OFF-LINE
COVER OPEN
OFF-LINE
DATA REMAIN
WAITING
HEAD THERMAL
WAITING
SP THERMAL
(2) Fault alarm display
When the printer detects any of the various alarm states, the information is displayed as
shown below on the operation panel. The alarm is specified by ALARM lamp and LCD Display.
(See Table 6.3 for details.)