EasyManua.ls Logo

Oki PACEMARK 4410 - 3.3.4 Power Supply Assy

Oki PACEMARK 4410
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40496501TH Rev.1 58
3.3.4 Power Supply Assy
(1) Remove Guide Paper (B), Cover Blank Lower and Rear Cover (B). (See 3.3.1)
(2) Unplug connectors to Power Supply Unit 1.
(3) Unscrew the screw 2 and release Earth Wire 3.
(4) Unscrew the screw 4 and remove Bracket PG 5.
(5) Unscrew 2 screws 6. Pulling forward the protrusion on Power Supply Unit 1 and sliding it
in the arrow direction through 2 inserting positions, remove Power Supply Unit.
(6) For installation, reverse the removal procedure.
(Note on Installation)
1. Insert the protrusion on Power Supply Unit 1 into the inserting positions on Lower Cover 7
and mount the Unit.
2. The fan should be installed, matching the direction of air flow to the direction of arrow shown
in the figure.
1
2
3
7
4
5
6
Protrusion
Air Flow

Table of Contents