INSTRUCTIONS
This instruction manual is for the Olympus Reflected Fluorescence System. To ensure the safety,
obtain optimum performance and to familiarize yourself fully with the use of this system, we
recommend that you study this manual thoroughly before operating the microscope. Retain this
instruction manual in an easily accessible place near the work desk for future reference.
A X 7 8 8 8
BX3-URA
BX3-RFAS
U-LH100HGAPO
U-LH100HG
U-RFL-T
U-AN-2
BX3-25ND6
BX3-25ND25
REFLECTED
FLUORESCENCE
SYSTEM

Questions and Answers

  • I
    iwhiteAug 6, 2025
    Why can't I see anything through my Olympus Microscope, even though the burner is on?
    • M
      Michael SmithAug 6, 2025
      If the burner is on but the image from your Olympus Microscope is dark, first ensure the shutter is open. Then, check if the ND filter is engaged and remove it if necessary. Verify that the fluorescence mirror unit is correctly engaged and matches the specimen. Also, make sure that the aperture and field iris diaphragms are centered and fully enlarged.
  • R
    Robert FarrellAug 11, 2025
    What to do if the field of view on my Olympus BX3-25ND25 is obscured?
    • C
      Courtney SilvaAug 11, 2025
      If your Olympus Microscope's field of view is obscured, ensure the objective and fluorescence mirror unit are correctly engaged in the light path. The revolving nosepiece and ND slider should click into place properly. Also, check that the field iris diaphragm is not set too small; center the aperture iris diaphragm and field iris diaphragm, then fully enlarge the field iris diaphragm. Finally, ensure the mercury burner is properly centered.
  • K
    Kaitlyn StephensAug 16, 2025
    Why is the mercury burner flickering on my Olympus BX3-25ND25?
    • L
      Leah MarshAug 16, 2025
      If the mercury burner of your Olympus Microscope flickers or appears dark, wait at least 10 minutes after ignition for it to stabilize. If the issue persists and the hour counter indicates 300 hours (USH-103OL), replace the mercury burner. Also, ensure the burner is centered on the optical axis.
  • L
    Laura ArmstrongAug 21, 2025
    How to improve the image quality of my Olympus BX3-25ND25?
    • M
      Mary MarshallAug 21, 2025
      If the image from your Olympus Microscope appears low quality, not sharp, or poor in contrast, start by thoroughly cleaning the objective and filter for any dirt or dust. Also, verify that the fluorescence mirror unit matches the specimen you are viewing.
  • D
    David HullAug 26, 2025
    What causes dark spots in the field of my Olympus Microscope?
    • J
      Jesse HarveyAug 26, 2025
      If your Olympus Microscope field contains dark, spot-like areas, the burner or the burner side of the collector lens may be dirty or dusty. Clean these components to resolve the issue.
  • C
    Christina FrancisAug 31, 2025
    Why won't the mercury burner light on my Olympus BX3-25ND25 Microscope?
    • D
      david37Aug 31, 2025
      If the mercury burner on your Olympus Microscope does not light even when the main switch is set to “I” (ON), first, ensure all connectors are firmly connected. Then, check that the mercury burner is properly attached. Verify that the safety device in the lamp housing is correctly set up. If auto ignition is malfunctioning, set the main switch of the power supply unit to “ ” (OFF) then “I” (ON) again, repeating as needed.

Summary

Important Safety and Usage Information

Nomenclature

Reflected Fluorescence Observation Procedure

Using the Controls

General Precautions for Observation

General safety and operational guidelines for using the reflected fluorescence system.

Selecting the Fluorescence Mirror Unit

Guidance on choosing the correct fluorescence mirror unit based on excitation light.

Turning the Power Supply Unit On

Steps to safely power on the unit and allow it to stabilize.

Centering the Field Iris Diaphragm

Procedure to center the field iris diaphragm for optimal image contrast.

Centering the Aperture Iris Diaphragm

Procedure for centering the aperture iris diaphragm on BX3-URA illuminator.

Centering the Mercury Burner

Steps to align the mercury burner for proper illumination.

Precise Mirror Centering

Advanced procedure for precise adjustment of the mirror position.

Mounting the ND Filters

Instructions for inserting Neutral Density filters to control light intensity.

Attaching the Light Shield Sheet

How to attach the light shield sheet to prevent image degradation.

Simultaneous Fluorescence Observations

Simultaneous Fluorescence and Phase Contrast

Procedure for combining reflected fluorescence with phase contrast observation.

Fluorescence and Transmitted Light DIC

Procedure for combining reflected fluorescence with DIC observation.

Troubleshooting Guide

Spectral Characteristics of Filters

Specifications

Assembly

Assembly Diagram

Diagram illustrating the sequence of assembling various microscope modules.

Detailed Assembly Procedures

Step-by-step instructions for assembling the microscope components.

Attaching Mercury Burner and Lamp Housing

Instructions for attaching the mercury burner and lamp housing.

Making Optional Fluorescence Mirror Units

Guide to fabricating custom fluorescence mirror units.

Lamp Housing Inspection Sheet

Proper Power Supply Cord Selection