BX40F
JE
A.
OUTLINE
OF
PRODUCT
OUTLINE
(1)
(2)
Application
Clinical
inspection
for
diagnosis
of
disease,
cells,
blood,
etc.
and
general
researches.
Product
range
Replacement
product
range
of
BHT and
BHTU
market.
FEATURES
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
The
field
number
22
(standard
field
of
view)
is
used
to
expand
the
observation
range
20%
compared
with
the
BH2.
The
arm
rest
(base)
is
eliminated
to
allow
the
operator
to
directly
put
his
hand
on
the
table
surface,
minimizing
the
operator's
fatigue
and
improving
the
maneuverability.
The
base-less
structure
expands
the
operation
space.
The
eye
point
height
is
adjustable
to
meet
the
operator
when
combined
with
U-TBI,
minimizing
the
operator's
fatigue
and
improving
the
workability.
The
wide
field
of
view
(field
number
26.5)
is
available
when
combined
with
the
superwide
field
observation
tube.
The
new
glass
material
and
coating
agent
used
in
the
UIS
optics
provide
an
image
with
sharp
contrast.
The
ceramic
coated
stage
is
equipped
as
a
standard
to
minimize
the
friction
of
the
slide
glass
on
the
stage
surface.
(The
wear
resistance
is
improved
to
eight
times
or
more
than
the
BH2-SVR(L).)
The
stage
control
knob's
rotating
force
is
adjustable
by
the
user
(40
~
400g
in
each
of
the
X
and
Y
direction).
The
revolving
nosepiece
facing
the
rear
side
is
used
to
facilitate
visual
inspection
and
marking
of
a
specimen.
Since
the
intermediate
lens
is
not
built
in
the
revolving
nosepiece,
it
prevents
deterioration
of an
image
by
the
intermediate
lens
and
allows
the
U-excited
observation.
The
light
preset
switch
allows
one-touch
switching
to
the
desired
light
level.
(This
is
useful
for
setting
the
color
temperature
of
photography
and
light
intensity
adjustment
when
switching
between
two
objectives.)
The
stage
stroke
is
increased
and
the
interference
between
the
specimen
holder
and the 40x
objective
is
eliminated
to
enable
observation
of
the
whole
surfaces
of
two
slide
glasses.
The
illumination
switch,
the
light
intensity
control
and
the
coarse
and
fine
adjustment
knob
are
located
in
a
concentrated
position
to
allow
operation
by
minimum
handling.
The
advanced
computer
simulation
based
on
the
finite
element
method
(FEM)
is
employed
to
improved
the
rigidity
and
stability
of
the
micro-
scope
frame.
The 30W
halogen
bulb
is
used
to
increase
brightness
and
to
allow
special
observation
such
as
darkfield
and
phase
contrast.