INSTRUCTIONS
CK30/CK40
CULTURE MICROSCOPE
This instruction manual is for the Olympus Culture Microscope Model CK30/CK40. To ensure the
safety, obtain optimum performance, and to familiarize yourself fully with the use of this microscope,
we recommend that you study this manual thoroughly before operating the microscope. Retain this
instruction manual in an easily accessible place near the work desk for future reference.
A X 7 1 6 2
Question and Answer IconNeed help?

Do you have a question about the Olympus CK40 and is the answer not in the manual?

Olympus CK40 Specifications

General IconGeneral
TypeBiological Microscope
Objectives4x, 10x, 40x, 100x (oil)
Magnification40x - 1000x
Illumination6V 20W halogen lamp
Eyepiece10x
CondenserAbbe condenser, NA 1.25
Power SupplyAC 100-240V, 50/60Hz

Summary

IMPORTANT

SAFETY PRECAUTIONS

Essential safety guidelines for operating and handling the microscope to prevent hazards.

Getting Ready

Maintenance and Storage

Caution

ASSEMBLY

Assembly Diagram

Diagram illustrating the sequence for assembling microscope modules.

Detailed Assembly Procedure

Step-by-step instructions for assembling the microscope components and accessories.

USING THE CONTROLS

Microscope Body Controls

Details on operating the microscope's main body controls, including power and brightness.

Stage Operation

Instructions for placing and moving specimens on the microscope stage.

Observation Tube Adjustments

Procedures for adjusting interpupillary distance and diopters for comfortable viewing.

PHASE CONTRAST OBSERVATION

Phase Contrast Parts

Identification of specific parts used for phase contrast observation, such as sliders.

Mounting 40 X Objective Light Annulus

Procedure for attaching the correct light annulus for 40X objectives in phase contrast.

Mounting the Phase Slider

Instructions for inserting the phase slider into the illumination unit slot.

Centering Light Annulus or Relief Slit

Steps to align the light annulus with the phase annulus for optimal phase contrast.

PHOTOMICROGRAPHY

Connecting Photomicrographic Systems

Guidance on connecting the microscope to various camera and imaging systems.

SPECIFICATIONS

TROUBLESHOOTING GUIDE

Optical System Troubleshooting

Troubleshooting common issues related to illumination and image quality in the optical system.

Electric System Troubleshooting

Resolving problems related to the microscope's electrical components and power supply.

Focusing Troubleshooting

Addressing difficulties with the coarse and fine adjustment knobs and focus issues.

Observation Tube Troubleshooting

Troubleshooting issues with eyepiece alignment and diopter settings.

Photomicrography Troubleshooting

Resolving problems encountered during photomicrography and image capture.

PROPER SELECTION OF THE POWER SUPPLY CORD