21
Getting Started
3
3.7 CONNECTING ANALOG AND RELAY OUTPUTS (Continued)
Figure 3-17. Relay Output Connections.
Figure 3-18. Isolated Analog Output Connections.
0—10VDC
0—20mA
4—20mA
OR
12 3
TB5
TB1 TB2
1234 1234
5678
56
789101112
Relay 1 Relay 2
N.O.1
N.C.1
COM1
N.O.2
N.C.2
COM2
}
}
TB1
123456
789101112
TB2
1234
5678
EXTERNAL LOAD
N
L
FUSE
NO2
COM2