EasyManua.ls Logo

Omron 3G3RX2-A2 Series - User Manual

Omron 3G3RX2-A2 Series
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
高機能型汎用バー
RX2シリーズ(形3G3RX2-□□□□□)
取扱説明書
PIM2824133-4A
NT3171
このたび形3G3RX2ズを買い求め誠にざいす。
の製品を安全に使用いに、お使いにる前に、の取扱説明書安全上のご注
び下記のマ熟読機器の知識、安全上の情報、注意事項の習熟
てから使してださいまたお読みになたあも、お使いになにはいつでも見られるうに、
本書ユーズマは、最終的にお使いる方のお手元も届取り計らい
お願いす。
OMRONCorporation2019AllRightsReserved.
ユーザーズマニアル SBCE-437

Questions and Answers

  • S
    Steven GilbertAug 22, 2025
    Why does my Omron Inverter show error E044?
    • H
      Heather WeberAug 22, 2025
      The E044 error on your Omron Inverter indicates that a subroutine, 'for next' command, or 'if' command is nested over eight levels. To resolve this, correct the program to ensure that the number of nesting levels is eight or less.
  • T
    turnermarkSep 1, 2025
    How to fix error E043 on an Omron 3G3RX2-A2?
    • M
      Meghan FisherSep 1, 2025
      The E043 error on your Omron Inverter means that the terminal PRG was turned ON even though no program was downloaded into the inverter. To fix this, you should create the program again and then download it to the inverter.
  • J
    Justin RossNov 11, 2025
    What to do if I get an E045 error on my Omron Inverter?
    • D
      Darlene ReyesNov 11, 2025
      If you encounter an E045 error on your Omron Inverter, it indicates a problem within the program. This could be due to several reasons: * The 'goto' command's jump destination is pointing to the 'next' command that terminates a loop: Correct the jump destination of the 'goto' command. * A four arithmetic operation results in overflow, underflow, or division by zero: Correct the program to prevent these errors. * The 'ChgParam' and 'MonParam' command is resulting in an error because you are trying to change a parameter that does not exist, the written value is out of range or you are trying to change a parameter value that cannot be changed during inverter operation or that is protected against change by the Soft Lock Selection. In this case you should: * Correct the parameter ...

Omron 3G3RX2-A2 Series Specifications

General IconGeneral
CategoryInverter
Frequency Control Range0.1 to 400 Hz
Enclosure RatingIP20
Series3G3RX2-A2
Output Frequency0 to 400 Hz
Current Range3.5 A
Control MethodV/f control, Sensorless vector control
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Ground fault
CommunicationRS-485 (Modbus ASCII/RTU)
Operating Temperature-10°C to +50°C (14°F to 122°F)
Storage Temperature-20 to +60°C (-4 to 140°F)
Cooling MethodFan Cooled

Related product manuals