EasyManua.ls Logo

Omron E5ARER - How to Use the Terminals; Connections

Omron E5ARER
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-6
How to Use the Terminals Section 3-2
Parts, Installa-
tion, and Wiring
3-2 How to Use the Terminals
Verify the layout of the terminals (A on and 1 on) using the engravings on the
top and sides of the case.
3-2-1 Connections
E5AR
E5AR-Q4B-DRT
6
5
4
3
2
1
6
5
4
3
2
1
A BEDC
KJIHGF
COM
SUB1
SUB2
COM
SUB3
SUB4
Auxiliary outputs
(Relay outputs)
3
6
5
4
2
1
EV2
COM
EV1
Event inputs
3
6
5
4
2
1
++
-
-
-
+
B
K
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5AR-A4B-500
E53-ARDRT
E5AR-A4B-500
DeviceNet Connector
Red (V+)
White (CAN H)
(Shield)
Blue (CAN L)
Black (V)
+
+
-
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA or
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output type setting.)
F
E53-ARQC
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5AR-A4B-500
100-240 VAC24 VAC/DC
+
-
-
+
E5AR-C4B-DRT
6
5
4
3
2
1
6
5
4
3
2
1
A BEDC
KJIHGF
COM
SUB1
SUB2
COM
SUB3
SUB4
Auxiliary outputs
(Relay outputs)
3
6
5
4
2
1
EV2
COM
EV1
Event inputs
3
6
5
4
2
1
++
-
-
-
+
B
K
TC
(Thermocouple)
PT
(Resistance thermocouple)
V
(Voltage)
I
(Current)
E5AR-A4B-500
E53-ARDRT
E5AR-A4B-500
+
+
-
-
3
6
5
4
2
1
OUT2
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output
type setting.)
OUT1
Current output
4-20 mA DC, 500
max.
0-20 mA DC, 500
max.
(Switch using output
type setting.)
F
E53-ARCC
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5AR-A4B-500
100-240 VAC24 VAC/DC
+
-
-
+
DeviceNet Connector
Red (V+)
White (CAN H)
(Shield)
Blue (CAN L)
Black (V)
E5AR-QC4B-DRT
6
5
4
3
2
1
6
5
4
3
2
1
A BEDC
KJIHGF
COM
SUB1
SUB2
COM
SUB3
SUB4
Auxiliary outputs
(Relay outputs)
3
6
5
4
2
1
EV2
COM
EV1
Event inputs
3
6
5
4
2
1
++
-
-
-
+
B
K
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5AR-A4B-500
E53-ARDRT
E5AR-A4B-500
DeviceNet Connector
Red (V+)
White (CAN H)
(Shield)
Blue (CAN L)
Black (V)
+
+
-
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA or
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output type setting.)
F
E53-ARQC
OUT3
Current output
4-20 mA DC, 500
max.
0-20 mA DC, 500
max.
(Switch using output
type setting.)
+
+
-
-
3
6
5
4
2
1
OUT4
Current output
4-20 mA DC, 500
max.
0-20 mA DC, 500
max.
(Switch using output
type setting.)
G
E53-ARCC
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5AR-A4B-500
100-240 VAC24 VAC/DC
+
-
-
+
E5AR-QQ4W-DRT (2-input Controller)
BEDC
K
6
5
4
3
2
1
6
5
4
3
2
1
JIHGF
A
COM
SUB1
SUB2
COM
SUB3
SUB4
Auxiliary outputs
(Relay outputs)
3
6
5
4
2
1
3
6
5
4
2
1
+
+
-
-
+
-
TC
PTVI
+
+
-
-
+
-
Input 1
Input 2
+
+
-
-
3
6
5
4
2
1
OUT4
Voltage output
12 V 40 mA
OUT3
Voltage output 12 V
40 mA or
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output type setting.)
+
+
-
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA or
Current output
4-20 mA DC, 500 max.
0-20 mA DC, 500 max.
(Switch using output type setting.)
G
F
B
K
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5AR-A4W-500
E5AR-A4W-500
E53-ARQC
E53-ARQC
E53-ARDRT
E5AR-A4W-500
100-240 VAC 24 VAC/DC
+
-
-
+
DeviceNet Connector
Red (V+)
White (CAN H)
(Shield)
Blue (CAN L)
Black (V)

Table of Contents