3-8
How to Use the Terminals Section 3-2
Parts, Installa-
tion, and Wiring
E5ER
E5ER-QTB-DRT
EDC
6
5
4
3
2
1
6
5
4
3
2
1
AB
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
+
+
-
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA
or
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARQC
EV2
COM
EV1
Event inputs
3
6
5
4
2
1
++
-
-
-
+
E
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-AB-500
Input power supply
depends on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AB-500
100-240 VAC
24 VAC/DC
+
-
-
+
E53-ARDRT
DeviceNet Connector
Red (V+)
White (CAN H)
− (Shield)
Blue (CAN L)
Black (V−)
E5ER-CTB-DRT
ED
C
6
5
4
3
2
1
6
5
4
3
2
1
B
A
+
+
-
-
3
6
5
4
2
1
OUT2
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARCC
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AB-500
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
100-240 VAC24 VAC/DC
+
-
-
+
E53-ARDRT
DeviceNet Connector
Red (V+)
White (CAN H)
− (Shield)
Blue (CAN L)
Black (V−)
EV2
COM
EV1
Event inputs
3
6
5
4
2
1
++
-
-
-
+
E
TC
(Thermocouple)
PT
(Resistance thermocouple)
V
(Voltage)
I
(Current)
E5ER-AB-500
E5ER-QTW-DRT (2-input Controller)
ED
C
6
5
4
3
2
1
6
5
4
3
2
1
B
A
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AW-500
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
3
6
5
4
2
1
+
-
+
-
TC
PTV
I
+
+
+
-
-
-
+
-
Input 1
Input 2
TC
(Thermocouple)
PT
(Resistance thermometer)
V
(Voltage)
I
(Current)
E5ER-AW-500
E
100-240 VAC24 VAC/DC
+
-
-
+
E53-ARDRT
DeviceNet Connector
Red (V+)
White (CAN H)
− (Shield)
Blue (CAN L)
Black (V−)
+
+
-
-
3
6
5
4
2
1
OUT2
Voltage output
12 V 40 mA
OUT1
Voltage output
12 V 40 mA
or
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARQC
E5ER-CTW-DRT (2-input Controller)
ED
C
6
5
4
3
2
1
6
5
4
3
2
1
B
A
+
+
-
-
3
6
5
4
2
1
OUT2
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output
type setting.)
OUT1
Current output
4-20 mA DC, 500 Ω max.
0-20 mA DC, 500 Ω max.
(Switch using output type setting.)
C
E53-ARCC
Input power supply depends
on the model.
100 to 240 VAC
or 24 VAC/DC (no polarity)
E5ER-AW-500
D
3
6
5
4
2
1
D
+
+
-
-
SUB1
SUB2
Auxiliary outputs
(Transistor outputs)
E53-ART2
100-240 VAC24 VAC/DC
+
-
-
+
E53-ARDRT
DeviceNet Connector
Red (V+)
White (CAN H)
− (Shield)
Blue (CAN L)
Black (V−)
3
6
5
4
2
1
+
-
+
-
TC
PTV
I
+
+
+
-
-
-
+
-
Input 1
Input 2
TC
(Thermocouple)
PT
(Resistance thermocouple)
V
(Voltage)
I
(Current)
E5ER-AW-500
E