EasyManua.ls Logo

Omron E5CC - Page 434

Omron E5CC
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I
I - 2
E5@C Digital Temperature Controllers User’s Manual (H174)
Numerics
2-PID control ......................................................4-14, 6-45
A
AD Converter Error ......................................................A-16
Adjustment Level ............................................... 6-18, A-26
Advanced Function Setting Level ...................... 6-61, A-32
air cooling/water cooling tuning ..................................... 5-9
alarm delays ................................................................ 5-26
alarm hysteresis .......................................................... 4-38
alarm latches ............................................................... 4-39
alarm operation ........................................................... 4-39
alarm outputs ............................................................... 4-32
alarm types .................................................................. 4-32
alarm values ................................................................ 4-35
alarms .......................................................................... 4-17
alarms (standard alarms) .............................................. 1-3
analog inputs ..........................................................5-5, 7-9
assigning outputs ........................................................ 4-16
AT (auto-tuning) .......................................................... 4-24
auto/manual control ..................................................... 5-13
auto-tuning (AT) .................................................4-24, 6-20
auxiliary output opening and closing in alarm ............. 4-19
auxiliary outputs 1 to 4 ................................................ 2-65
C
calibrating a current input .............................................. 7-9
calibrating a voltage input ............................................ 7-11
calibrating inputs ........................................................... 7-2
calibrating the transfer output ...................................... 7-13
characteristics ...............................................................A-4
checking indication accuracy ....................................... 7-15
analog input ........................................................... 7-17
infrared temperature sensor .................................. 7-15
resistance thermometer ......................................... 7-16
clearing the program end status .................................. 5-45
cold junction compensator ........................................... 7-15
communications .......................................................... 2-71
communications operation command .......................... 5-21
Communications Setting Level .......................... 6-96, A-38
component communications ....................... 1-4, 6-96, A-38
CompoWay/F .................................................... 6-96, A-38
connecting the cold junction compensator .................... 7-5
control outputs ......................................................1-3, 4-18
control outputs 1 and 2 ................................................ 2-62
control periods ............................................................. 4-15
control ranges ..............................................................A-43
controlling the start of the simple program function ..... 5-13
CT
dimensions ............................................................A-10
E54-CT1 ........................................................A-10
E54-CT3 ........................................................A-11
E54-CT3/CT3L ..............................................A-11
specifications .........................................................A-10
CT inputs ..................................................................... 2-69
current transformer (CT) .................................... 4-44, A-10
Current Value Exceeds ...............................................A-17
D
dedicated protocol (format 4) ............................ 6-96, A-38
derivative time ............................................................. 4-31
detection current values ..............................................4-46
Digit Shift Key ................................................................ 3-9
dimensions .................................................................... 2-2
direct and reverse operation ........................................4-15
Display Range Exceeded ............................................A-16
displaying changed parameters ..................................5-22
Down Key (D Key) ....................................................... 3-7
E
End Plate installation ...................................................2-13
error displays ...............................................................A-15
event inputs .................................................1-4, 2-66, 5-11
extraction of square roots ............................................5-51
F
front panel .....................................................................3-4
E5AC ....................................................................... 3-5
E5CC/E5CC-U/E5CC-B ...........................................3-4
E5DC/E5DC-B ......................................................... 3-5
E5EC/E5EC-B .........................................................3-4
E5GC ....................................................................... 3-6
H
HB alarm ....................................................4-40, A-3, A-17
heater burnout alarm ........................................... 6-65, A-3
heater short alarm ............................................... 4-40, A-3
heating/cooling control .........................................5-7, 6-46
HS alarm ....................................................4-42, A-3, A-17
HS alarms ......................................................................1-3
I
I/O configuration ............................................................1-5
model number legend ............................................1-10
indication ranges .........................................................A-43
infrared temperature sensor ........................................ 7-15
initial setting example
example 1 ................................................................4-8
example 2 ................................................................4-9
initial setting examples ..................................................4-8
Initial Setting Level ..................................... 3-4, 6-41, A-28
initialization .........................................................5-75, 6-63
Input Error ...................................................................A-15
input error .................................................................... 6-33
input sensor types ......................................................... 1-3
input type .....................................................................4-11
inputs ........................................................................... 2-61

Table of Contents

Other manuals for Omron E5CC

Related product manuals