2.3 Detailed Description of the Services
2-15
Operation Command
This service performs operations such as run/stop, communications
writing, write mode, save RAM data, AT (auto-tuning) execution/cancel,
multi-SP, move protect level, move to setup area 1, and software reset.
Service Request PDU
Service Response PDU
(1) Command Code and Related Information
Note: No response will be returned when a software reset is carried out.
(2) Response Code
Normal Completion
Command
code
Command content Related Information
00 Communications writing 00: OFF (disabled)
01: ON (enabled)
01 RUN/STOP 00: Run
01: Stop
02 Multi-SP 00: Set point 0
01: Set point 1
02: Set point 2
03: Set point 3
03 AT execute/cancel 00: Cancel
01: AT execute
04 Write mode 00: Backup
01: RAM
05 Save RAM data 00
06 Software reset (See note.) 00
07 Move to setup area 1 00
08 Move to protect level 00
09 Auto/manual switch 00: Automatic mode
01: Manual mode
0B Parameter initialization 00: Initialize to defaults
01: Initial settings service values
11 Program start 00: Reset
01: Start
Response code Name Description
0000 Normal completion No errors were found.
MRC SRC
3005
2222
Com-
mand
code
Related
informa-
tion
MRC SRC
3005
22 4
Response
code

Table of Contents