Com Data
SECTION 3 Communications Data for CompoWay/F and SYSWAY
3-4
C1 000D Heater burnout 1
detection
H'00000000 to H'000001F4 (0.0 to 50.0) Adjust-
ment
C1 000E Set point 0 SP lower limit to SP upper limit
C1 000F Set point 1 SP lower limit to SP upper limit
C1 0010 Set point 2 SP lower limit to SP upper limit
C1 0011 Set point 3 SP lower limit to SP upper limit
C1 0012 Temperature input
shift value
H'FFFFF831 to H'0000270F (−199.9 to 999.9)
C1 0013 Upper-limit tempera-
ture input shift value
H'FFFFF831 to H'0000270F (−199.9 to 999.9)
C1 0014 Lower-limit tempera-
ture input shift value
H'FFFFF831 to H'0000270F (−199.9 to 999.9)
C1 0015 Proportional band H'00000001 to H'0000270F (0.1 to 999.9)
C1 0016 Integral time H'00000000 to H'00000F9F (0 to 3999)
C1 0017 Derivative time H’00000000 to H’00000F9F (0 to 3999) (Range when RT is
“OFF”)
H’00000000 to H’0000270F (0.0 to 999.9) (Range when
RT is “ON”)
C1 0018 Cooling coefficient H'00000001 to H'0000270F (0.01 to 99.99)
Vari-
able
type
Ad-
dress
Parameter name Setting (monitor) value Level