Item
Connected camera, Light-
ing controller
, and Light-
ing type
FH-2050 FH-2050-10 FH-2050-20
Recom-
mended
Power
Source
S8VK-G
S8VS
When connecting intelli-
gent compact digital cam-
eras:
When connecting the fol-
lowing lightings or light
controllers without exter-
nal power supplies:
FL
V-TCC1
FLV-TCC4
FLV-TCC3HB
FLV-TCC1EP
FL-TCC1
When connecting the fol-
lowing lighting or light
controllers:
FL-TCC1PS
FL-MD£MC
S8VK-G12024
S8VS-12024
S8VK-G24024
S8VS-18024
S8VK-G48024
S8VS-48024
Other than above case S8VK-G12024
S8VS-09024
S8VK-G12024
S8VS-12024
S8VK-G24024
S8VS-18024
Mounting of FH-1000/2000/3000/5000 Series
Make sure to tighten all screws in mounting.
For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clearance of
30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are also required when
mounting multiple Sensor Controllers side by side. For the back mounting, the back-side clearance
of 15 [mm] is not required.
Do not install the product immediately above significant heat sources, such as heaters, transform-
ers, or large-capacity resistors.
Do not install the Sensor Controller in a cabinet with high-voltage equipment installed.
Mount the Sensor Controller at 200 [mm] or more from power cables apart.