5-4-3
FH-L Series
Precautions for Safe Use
• Monitor connector: Please insert the connector perpendicularly so that the connector resin
part and pin are not rubbing against each other
. Damaged pin may cause contact failure due
to generation and invasion of resin powder.
• Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and FH-MT12 using a USB cable. The internal circuits may cause a short-circuit
and result in malfunction.
Precautions for Correct Use
When connecting the sensor controller and monitor with a switcher and splitter
Do not use devices that may require re-recognition of the monitor by the Sensor Controller
when a switching operation was performed. If such re-recognition processing happens at
switching operation, it may cause measurement time to be longer
.
When fix the DVI connector
If difficult to fix the bilateral screws of DVI connector, once loosen these. Then retry to fix, again.
5 Setup and Wiring
5-23
FH Series Vision System Hardware Setup Manual (Z366-E1)
5-4 Setup Touch Panel Monitor or Monitor
5
5-4-3 FH-L Series