Precautions for Correct Use
Installation and Storage Sites (FH-1000/2000/3000/5000 series)
Install and store the product in a location that meets the following conditions:
Surrounding temperature of 0 to +50°C
*1
(-20 to +65°C in storage)
*1. FH-5000 Series: Surrounding temperature of 0 to 45°C
No rapid changes in temperature (place where dew does not form)
Relative humidity of between 35 to 85%
No presence of corrosive or flammable gases
Place free of dust, salts and iron particles
Place free of vibration and shock
Place out of direct sunlight
Place where it will not come into contact with water, oils or chemicals
Place not affected by strong electro-magnetic waves
Place not near to high-voltage, or high-power equipment
Installation and Storage Sites (FH-L series)
Install and store the product in a location that meets the following conditions:
Surrounding temperature of 0 to +55°C (-25 to +70°C in storage)
No rapid changes in temperature (place where dew does not form)
Relative humidity of between 10 to 90%
No presence of corrosive or flammable gases
Place free of dust, salts and iron particles
Place free of vibration and shock
Place out of direct sunlight
Place where it will not come into contact with water, oils or chemicals
Place not affected by strong electro-magnetic waves
Place not near to high-voltage, or high-power equipment
Orientation of Product
For efficient heat dissipation, install the product only with the orientation written in this manual or the
Instruction Sheet. Install the product so that the air can flow freely through its cooling vents.
Ambient Temperature
To secure good ventilation, install the product with clearance written in this manual or the Instruction
Sheet.
Do not install the product immediately above significant heat sources, such as heaters, transform-
ers, or large-capacity resistors.
Use the product within the operating temperature range based on the specifications of it.
Install a forced cooling fan or air conditioner not to exceed the operating temperature range when
the ambient temperature is close to the upper limit of its range.
Precautions for Correct Use
20
FH Series Vision System Hardware Setup Manual (Z366-E1)