5-5-2
FH-1000/2000/3000/5000 Series
Precautions for Safe Use
Ground
When a base is packed in a camera that will be connected to the Sensor Controller
, make
sure to mount the camera using the base. Since the enclosure of the camera body is
connected to the internal circuits, mounting the camera without using the base allows the in-
ternal circuits to be directly connected to the ground, which may cause malfunction or failure.
Connect the FH-1000/2000/3000/5000 Series to FH-SC12/FH-SM12 (12 megapixels cam-
era)
Do not ground the positive terminal of the 24 VDC power supply when connecting the Sensor
Controller and a 12 megapixels camera like FH-SC12 or FH-SM12.
Mounting of Ferrite core
Mount the ferrite core attached to the camera cable to near the Sensor Controller.
Camera cable mounting
Connect the cable with securing the connector length and the minimum bending radius to the Sensor
Controller
.
Minimum
bending radius
Connector length
Name Model
Minimum bending
radius
Connector length
Camera Cable FZ-VS3
69 [mm] 30 [mm]
Right-angle Camera Cable FZ-VSL3
Bend resistant Camera Cable FZ-VSB3
Bend resistant Right-angle Camera Cable FZ-VSLB3
Long-distance Camera Cable FZ-VS4
78 [mm] 42 [mm]
Long-distance Right-angle Camera Cable FZ-VSL4
5 Setup and Wiring
5-25
FH Series Vision System Hardware Setup Manual (Z366-E1)
5-5 Camera Installation
5
5-5-2 FH-1000/2000/3000/5000 Series