4 Secure the terminal block connector (male) by tightening the screws on the right and left sides
of it with a flathead screwdriver
. Recommended tightening torque: 0.5 to 0.6 N•m
Terminal block connector (female)
Terminal block connector (male)
18.215.854.7
8.3
15
5.08 5.08
(Unit: mm)
Recommended Power Source for FH-L Series
The power source connected to the FH-L series Sensor Controller changes the power consumption
depending on the number of camera. Refer to the following table.
When you connect the camera using lighting Controller
, the power consumption is same when connect
to the Intelligent Compact Digital Camera.
Item Camera type No. of camera
FH-L£££ FH-L£££-££
Recommended
Power Source
S8VK-G
S8VS
Intelligent Compact
Digital Camera
2 S8VK-G12024
S8VS-09024
S8VK-G12024
S8VS-09024
4
-
S8VK-G12024
S8VS-12024
Camera of
0.3/2/4/5/12 million
pixels
2 S8VK-G06024
S8VS-06024
S8VK-G06024
S8VS-06024
4
-
S8VK-G06024
S8VS-06024
5 Setup and Wiring
5-14