Minimum
bending radius
Connector length
Name Model
Minimum bending
radius
Connector length
Camera Cable FZ-VS3
69 [mm] 30 [mm]
Right-angle Camera Cable FZ-VSL3
Bend resistant Camera Cable FZ-VSB3
Bend resistant Right-angle Camera Cable FZ-VSLB3
Long-distance Camera Cable FZ-VS4
78 [mm] 42 [mm]
Long-distance Right-angle Camera Cable FZ-VSL4
Installation in a Control Panel
• Make sure to tighten all screws in mounting.
•
For good ventilation, provide a clearance of 50 [mm] or more above the Sensor Controller away
from other devices in the normal floor mounting. For the right and left sides, provide a clearance of
30 [mm] or more, and for the back side, 15 [mm] or more. These clearances are also required when
mounting multiple Sensor Controllers side by side. For the back mounting, the back-side clearance
of 15 [mm] is not required.
l
Mounting the base of the Sensor Controller (Floor mounting)
Clearance: 50 mm
Clearance: 30 mm
Clearance: 15 mm
Clearance: 30 mm
5 Setup and Wiring
5-34
FH Series Vision System Hardware Setup Manual (Z366-E1)