46
System Specification Section 15-1
Electrical
Power Input Transmitter 24 VDC ±20%, maximum current 285 mA
MTS Input 24 VDC ±20%, 20 mA typ.
Power Input Receiver 24 VDC ±20%, maximum current 1835 mA
Receiver 485 mA + AUX 100 mA +
OSSD1 625 mA + OSSD2 625 mA
Leakage current < 1mA
Capacitive Load < 4.7µF for OSSD output
Inductive Load Please contact your Omron representative for further
information.
Test pulse data
t1: Test pulse ≤ 600 µs
t2: 4 ms ≤ Test interval ≤ 40 ms
t3: Repetition ≤ 5min
Muting Option 24 VDC ±20%, 30 mA max.
Muting Duration Approx. 2 min. or No time limit
Power Supply Must meet the requirements of EN/IEC 60204-1 and
EN/IEC 61496-1, and must guarantee safe insulation
from the mains voltage in accordance with IEC 60742
and be able to cover a drop of supply voltage of at least
20 ms.
Protection class
(IEC 536 or VDE 106)
III
Environmental
Enclosure Rating IP65
Operating Temperature -10°C … +55°C
Storage Temperature -25°C … +70°C
Relative Humidity 95% maximum, non-condensing
Vibration (IEC 60068-2-6) 10 - 55 Hz, 10g, maximum on all 3 axes
Shock (IEC 60086-2-29) 10g for 16 ms, 1000 shocks on all 3axes
Connections
Cable length
MS4800 Transmitter
Unshielded cables:
Max. 50 m, @ 0.32 mm²
We recommend to use the F39-JMT cables or as
alternative the F39-TGR-CVL-B-_E (shielded) to
connect the MS4800 system to the machine control
system.
Cable length
MS4800 Receiver
Unshielded cables, length is depending on the maxi-
mum current consumption:
OSSD 1&2-load 625 mA: 12 m @ 0.5 mm²
OSSD 1&2-load 300 mA: 45 m @ 0.5 mm²
We recommend to use the F39-JMR cables or as
alternative the F39-TGR-CVL-B-_R (shielded) to
connect the MS4800 system to the machine control
system.
Cable length
MS4800FS system
Shielded cables, M12 connector 4-pin, these cables are
available as accessories. Maximum length is 10 m
between segments
OSSD 1
OSSD 2
t
1
t
2
t
3
t