45
SECTION 15
Specifications and additional information
15-1 System Specification
Performance
Protective height 240 mm - 1800 mm (14 mm resolution)
280 mm - 2120 mm (30 mm resolution)
Object Resolution 14 mm and 30 mm
Operating Range 0.3 m - 7 m (14 mm resolution), DIP SW 6 option
0.3 m - 3 m (14 mm resolution), default
0.3 m - 20 m (30 mm resolution), DIP SW 6 option
0.3 m - 8 m (30 mm resolution), default
Effective Aperture Angle ±2,5° maximum, transmitter and receiver according to
IEC61496-2 (2006)
Safety Output (OSSDs) Two PNP safety outputs, each output sourcing
625 mA @ 24 VDC.
Short circuit protection
Response Time Maximum: 59 ms
See table below for more details
Auxiliary Output
(non safety)
One PNP output sourcing 100 mA @ 24 VDC. This out-
put follows the OSSDs.
EDM - Monitor Input 50 mA @ 24 VDC
Start/Restart Input 10 mA @ 24 VDC, Normally open input
Light Source Infrared Emitting LEDs,
Wavelength 880 nm
Power Dissipation: 180 mW
Class 1 per EN60825-1
Transmitter Indicator Lights ACTIVE (Yellow)
Receiver Indicator Lights MACHINE RUN/STOP (Green/Red)
INTERLOCK/ALARM (Yellow)
BLANKING (Amber)
Mechanical
Housing Material Polyurethane powder painted aluminum
Front Window Material Acrylic, Red
End Cap Material Polycarbonate
Mounting Bracket Material Cold rolled Steel
Wiring connections M12-connectors;
8-pin receiver and 5-pin transmitter
Weight See table for more details