General Mounting Considerations Section 10-3
10-3 General Mounting Considerations
10-3-1 Additional Guarding
Areas of access to the point of hazardous operation not guarded by the
MS4800 system must be protected by suitable means such as a fixed barrier
guard, an interlocked guard or a safety mat system.
10-3-2 Added Mounting Rigidity
It is recommended that when installing a
MS4800 larger than 1000 mm in length,
you use an additional mounting bracket.
This is to be installed using the T-slot on
the backside of the transmitter and
receiver.
Note
For light curtain > 1000 mm its recom-
mended to buy extra T - slot mounting
bracket as Accessory.
Supplemental
Guarding
Supplemental
Guarding
Hazard
Zone
D
s
LIGHT CURTAIN
Supplemental
Guarding
Example
Mechanical
Barrier
Supplemental
Guarding
Supplemental
Guarding
MS4800 point of
operation guarding
MS4800FS 3-sided guarding MS4800FS 2-Axis guarding
ALTERNATE
T-SLOT
MOUNTING
ALTERNATE
T-SLOT
MOUNTING