36
Interconnect cables for cascaded MS4800FS system Section 11-1
TGR cables
Note Alternative cables:
F39-TGR-CVL-B-_ cables are industry standard shielded cables with a M12
female connector.
11-1 Interconnect cables for cascaded MS4800FS system
The segment-to-segment cable has a 4 contact M12 connector on each end.
The maximum cable length is 10 meters between segments.
The extension cables are available in lengths of 0.3 m, 0.5 m, 1 m, 2 m, 5 m
and 10 m. A MS4800FS system does not require an extension cable; it has a
150 mm integrated cable (pigtail).
MS4800FS systems are designed with internal circuit protection to protect
from damage when they are connected and disconnected (hot-swap) during
normal operation.
Length Receiver Transmitter
2 m F39-TGR-CVL-B-2-R F39-TGR-CVL-B-2-E
5 m F39-TGR-CVL-B-5-R F39-TGR-CVL-B-5-E
10 m F39-TGR-CVL-B-10-R F39-TGR-CVL-B-10-E
Receiver cable
Pin No. 1 Test Input white
Pin No. 2 Input Power + 24 VDC brown
Pin No. 3 Input Power GND Blue
Pin No. 4 OSSD2 pink
Pin No. 5 OSSD1 gray
Pin No. 6 Muting B yellow
Pin No. 7 Muting A Green
Pin No. 8 Muting lamp connection LMS red
Transmitter cable
Pin No. 1 Test Input white
Pin No. 2 Input Power + 24 VDC brown
Pin No. 3 Input Power GND Blue
Pin No. 4 Not used black
Pin No. 5 Not used green
Transmitter Master
10 m -> Slave 1 10 m -> Slave 2 10 m -> Slave 3
Receiver Master
10 m -> Slave 1 10 m -> Slave 2 10 m -> Slave 3 30 m -> RM6