EasyManua.ls Logo

Omron MS4800E - Safety Distance and Beam Heights in Access Guarding

Omron MS4800E
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
Safety distance and beam heights in access guarding Section 9-3
9-3 Safety distance and beam heights in access guarding
!WARNING Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
According to EN999 and EN294:
The height of the protective field "H" above the reference plane and the reso-
lution "d" of the MS4800 system have the following relationship:
S = (K x T) + C
For K and T please refer to the previous chapter
C = 8 x (d - 14)
d = resolution of the MS4800 system
S = (2000 mm x T) + 8 x (d - 14)
H
S
L
Direction of
approach
Resolution Lowest beam above
reference plane
Highest beam above
reference plane
Additional
amount C
(see formula)
14 mm In accordance with
EN 294
In accordance with
EN 294
0mm
30 mm In accordance with
EN 294
In accordance with
EN 294
128 mm

Table of Contents