6.DeviceNet Settings
6. DeviceNet Settings
This section provides specifications such as communications parameters and variables that
are defined in this document.
6.1. DeviceNet Communications Settings
The following are the settings for DeviceNet.
CJ1W-DRM21 NE1A-SCPU01-V1
Unit number 0 -
Node address (MAC ID) 63 0
Baud rate (bps) 500 kbps 500 kbps
Additional Information
To monitor the Safety Network Controller from the Controller, set the Controller as a Standard
Master and set the Safety Network Controller as a Standard Slave on DeviceNet.
Establish a connection between the Standard Master and the Standard Slave to monitor the
data. With the connection, not only Safety I/O communications but also standard I/O
communications are performed.
Machine Automation
Controller
Safety Network
Controlle
Standard Master
Standard Slave
Connection
Additional Information
When a DeviceNet Unit is used with a Controller, slave data are allocated to the memory
used for CJ-series Units. With programs, specify variable names for the memory used for
CJ-series Units.
With Sysmac Studio, add the prefix "%" to each address to indicate the memory used for
CJ-series Units.