Event code Event name Meaning Assumed cause
Level
Reference
M
a
j
P
rt
M
i
n
O
b
s
I
n
f
o
35270000 hex
[NX-SL5£££]
Safety Unit
Restore Op-
eration
Failed to
Start (Model
Mismatch)
A model mismatch
was detected during
pre-execution checks
for a restore opera-
tion for a Safety Unit.
The restore operation for a
Safety Unit was performed on
an incorrect unit.
An incorrect Safety Unit Re-
store File was used.
¡
page
12 - 61
35280000 hex
[NX-SL5£££]
Safety Unit
Restore Op-
eration
Failed to
Start (Ver-
sion Mis-
match)
A version mismatch
was detected during
pre-execution checks
for a restore opera-
tion for a Safety Unit.
The restore operation for a
Safety Unit was performed on
an incompatible unit.
An incorrect Safety Unit Re-
store File was used.
¡
page
12 - 62
35290000 hex
[NX-SL5
£££]
Safety Unit
Restore Op-
eration
Failed to
Start (Node
Name Mis-
match)
A node name mis-
match was detected
during pre-execution
checks for a restore
operation for a Safety
Unit.
The restore operation for a
Safety Unit was performed on
an incorrect unit.
An incorrect Safety Unit Re-
store File was used.
The node name specified
when the Safety Unit Restore
File was generated is incor-
rect.
¡
page
12 - 63
352A0000 hex
[NX-SL5£££]
Safety Unit
Restore Op-
eration
Failed to
Start (Safety
Password
Mismatch)
A safety password
mismatch was detect-
ed during pre-execu-
tion checks for a re-
store operation for a
Safety Unit.
The restore operation for a
Safety Unit was performed on
an incorrect unit.
An incorrect Safety Unit Re-
store File was used.
The safety password specified
when the Safety Unit Restore
File was generated is incor-
rect.
¡
page
12 - 64
352B0000 hex
[NX-SL5£££]
Safety Unit
Restore Op-
eration
Failed
The restore operation
for a Safety Unit
ended in an error.
The SD Memory Card was re-
moved during a restore opera-
tion for a Safety Unit.
Data was read from or written
to the SD Memory Card via the
Support Software or an FTP
client during a restore opera-
tion for a Safety Unit.
¡
page
12 - 65
l
Other Errors
12 Troubleshooting
12 - 25
NX-series Safety Control Unit User's Manual (Z930)
12-3 Checking for Errors with the Sysmac Studio
12
12-3-3 Event Codes for Errors and Troubleshooting Procedures

Table of Contents