New S82K
6
Specifications
Ratings/Characteristics
3- to 240-W models without PFC
Item
Single output Dual
outputs
Single output
3W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W
Efficiency (typical)
60% to 80% (Varies depending on specifications.)
Input Voltage
(see note 1)
AC
100 to 240 V (85 to 264 V) 100 V (85 to 132 V)/
200 V (170 to 264 V)
Selectable
100 V (85 to
132 V)/
200 V (170
to 253 V)
Selectable
DC
90 to 350 V (see note 2) Not possible
Frequency
50/60 Hz (47 to 450 Hz)
Current
(see note 3)
100-V
input
0.15 A
max.
0.25 A max.
0.45 A
max.
0.9 A
max.
1.3 A
max.
2.5 A max. 5.5 A max.
(
s
e
e
o
e
3
)
200-V
input
0.25 A
max.
0.6 A
max.
0.8 A
max.
1.5 A max. 3.5 A max.
Power factor
---
Leakage
current
(
)
100-V
input
0.5 mA max.
c
u
e
(see note 3)
200-V
input
1mAmax.
Inrush
current
(
)
100-V
input
15 A max. 25 A max.
c
u
e
(see note 3)
200-V
input
30 A max. 50 A max.
Noise filter
Yes
Note:
1. Use with DC voltage input is beyond the conditions of approval or conformance to applicable safety standards.
2. Use the 7.5-W single-output models under the load of 90% max. if the voltage range is between 90 and 1 10 VDC.
3. Defined with a 100 % load and the rated input voltage (100 or 200 VAC).