EasyManua.ls Logo

Omron SYSDRIVE 3G3JV

Omron SYSDRIVE 3G3JV
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-14
3G3JV-A10023G3JV-A1001100-V AC Models
Protective
fi
Motor protection Protection by electronic thermal
functions
Instantaneous overcurrent
protection
Stops at approx. 250% of rated output current.
Overload protection Stops in 1 min at approximately 150% of rated output cur-
rent.
Overvoltage protection Stops when main-circuit DC voltage is approximately 410 V.
Undervoltage protection Stops when main-circuit DC voltage is approximately 160 V.
Momentary power interruption
compensation (selection)
None (Stops at 15 ms or longer.)
Select between continuing operation if power is restored
within approx. 0.5 s or continuing operation regardless of
length of interruption.
Radiation fin overheated Detected at 110°C ±10°C
Grounding protection Rated output current level protection
Charge indicator CHARGE indicator lights until the main circuit DC voltage
reaches 50 V or less.
Environ-
Location Indoors (with no corrosive gas, dust, etc.)
ment
Ambient operating temperature –10 to 50°C
Ambient operating humidity 95% max. (with no condensation)
Storage temperature –20 to 60°C
Altitude 1,000 m max.
Insulation resistance 5 M min. (Do not carry out any insulation resistance or
withstand voltage tests.)
Vibration resistance 9.8 m/s
2
max. between 10 and 20 Hz, 2.0 m/s
2
max. be-
tween 20 and 50 Hz
Degree of protection Mounted in a panel (equivalent to IP20)
Design Chapter 1